240 volt 3 phase motor wiring diagram. The voltage is applied directly to one hot wire and the other hot is joined together with the neutral wire. 240 volt 3 phase motor wiring diagram

 
 The voltage is applied directly to one hot wire and the other hot is joined together with the neutral wire240 volt 3 phase motor wiring diagram  High performance ball bearings

For example, use 12# or 4. B. The label details show the scale of the motor and electric demands. Close the motor's wiring box. Three-phase installations could be 240 volt, 3 wire, 480 volt 3 wire, 600 volt, 3 wire, 208Y/120 volt, 4 wire , or 480Y/277 volt, 4 wire. . Baldor Motor Wiring Diagram 3 Phase Source: static-resources. Pretty much everywhere else in the world, 240V (nominal) is Hot and Neutral. The first step in wiring a 3 Phase 480V motor is to determine the total voltage of the motor. Search. This will cause the magnetic field to change directions, and the motor will follow. The electrical riser diagram shows 120/240 volt 3 phase. Contactor – The contactor is the switch that turns the power on and off. Figure 1. 2A. OR get an inverter, simply provide a 220V single phase (Line and neutral of the 380V supply) to it and get a 220V 3 phase. All wiring and electrical connections should comply with the National Electrical Code (NEC) and with local codes and practices. Gray = Phase 3 or Line 3. This video explains how to wire a three-phase induction motor to an external electricity source. Try to test run the appliance to make sure that it is working properly. For example: L1 and L2 indicate that the motor voltage may be 240 volts. 2 Kva Transformer Primary 240x480 Secondary 120 240 Jefferson 411 0091 000. In the above diagram, the alternator is connected to the load by three phase four. The way you make up the motor will be dependent upon the voltage. You're describing "high leg" or "wild leg" delta. White Wire: Splice to Wires T8, T4 & T2 (marked with Wire P1 white tape) Wire T8 Wire T4 Wire T2 Wire P2 (marked with yellow tape: Do not modify) Wire T3 Wire T5 Clear connector (do not modify) Power Green Wire x. Motor: 1~. I have attached an image of the correct wiring diagram copied from your picture. certain specially designed circuits of each phase of the primary winding are initially connected to the supply line. Turn on the appliance. There are four basic wiring combinations: a) Full-voltage non-reversing 3-phase motors. Check the paired wires for resistance. Use a capacitor rated for motor run use, or power factor correction capacitor (s). They. 7 A = 2 kVA 1000 Three-Phase kVA = Load Volts x Load Amperes x. If this motor is installed as part of a motor control drive system, connect and protect the motor according to the control manufacturers diagrams. Minimum Copper Wire Size: #6 – (Wire Types THW, THHN, THWN are Rated at 65 Amps). We will also. Also if you are in North America, that motor will spin 20% (6/5). Electrical Contacts - Normally Open And Normally Closed Contacts. Aug 6,. total power in a Three Phase. I will check to verify if the utility has grounded the transformer at the pole. Thanks. Then of course 3 capacitors. Motor control wiring diagram. 120/240 Volt, 3 Phase, 4-Wire. With the U, V, W pairs that looks more like a three-phase motor modified to run on single phase. Three-phase motors are more efficient than single phase motors and are commonly found in applications requiring more than 7. It provides an easy-to-understand visualization of the connection between the pole windings, load and auxiliaries. 3 Phase Motor Starters and Control Circuits. 144 KW Kilowatts. Finally, use electrical tape to cover any exposed wires to prevent shorts or shocks. You can now turn on the power to your motor and test that the switch works. A 208v three phase wiring diagram is a blueprint that shows the electrical connections between various devices in an industrial or commercial setting. Connect the ground wire to the motor's ground terminal. In case of three phase spa wiring, use 12 or 10 gauge wire size for each line. 120 V circuits are the most. High-leg Delta systems offer voltage flexibility that the wye configuration lacks as it. Since it is rather easy to build a motor suitable for use on two voltages. By design however, this setting can be switched – and switching between the. 115V 60Hz. A single-phase wire generally reads 120 volts between a hot and ground, but 240 volts between the two hot. The three phase power supply consists of three individual lines power supply, each with its own voltage and current capacity. In the US 120 / 240V 1 Phase 3 Wire is the. Photo 4This Magnetic Starter is a 3 phase, full voltage across the line starter with the coil factory wired for 208-240 volts (Figure B). If you are only using it for a safety not opening and closing under load it might hold up. This video discusses a 120/240V Three-Phase Four-Wire Delta System. The wires are color coded, typically black and red. For example, the diagram may include labels such as “L1”, “L2”, “L3” and “C”. Other types of three-phase supplies are wye connections, ungrounded delta connections, or corner-grounded delta ("ghost" leg configuration) connections. Incoming DE1 wiring configuration Table 1. 5kW (10HP) in domestic areas (consumer unit for home). But please consider your Inverter current (ampere) rating same rated or higher than motor FLA. 5129 Login or Sign Up; 0. Having a basic understanding of such diagrams can help determine potential issues that should be addressed before running the motor, and. Motor Switch: The motor switch is used to turn the power on and off. I have little experience with 3 phase but I am more familiar with 120/208. Three-phase power from a single-phase source anywhere you need it. connect leads 2,3,5 together (without connecting them to either power lead) Connect the other power lead to 4,6. I attempted to wire it for 115. 1. One other important difference between 3-phase power vs. (1) The following links are pre-fitted to the. I need a 3 phase distribution transformer (10 -15 kva) to provide 120 volts power to appliances. 3 Phase For The Vs 1 Power Making With Metal. When it comes to wiring a transformer for 480 volts 3 phase to 120/240 volts single phase, there are several important considerations to bear in mind. A 120/240 volt single phase panel found at a home or shop can only provide up to two separate lines of power, therefore this type of electrical service could not provide the necessary power for a 3 phase motor. A volt meter test on the unit first if it is currently on 3ph, first and note the on-off cycles. This diagram will also include all of the safety measures and switches that should be in place to help protect the circuit and its components from damage. The 220-volt circuits as they were known prior to the 1960s are now commonly known as 240-volt circuits and 110-volt circuits are now 120-volt circuits. So if A-B, B-C and C-A are all 240 volts, then A-N and C-N will both be 120 volts, but B-N will be 208 volts. In this video I will show you how to set up a 3 phase air compressor wire connection. Next, you are required to insert the ground wire to provide a ground screw. Wiring 220-volt boxes and motors is serious business. . . For instance , if a module will be powered up and it sends out a new signal of 50 percent the voltage and the technician does not know this, he would think he offers a problem, as he would expect a. 1/2 - 25 hp. TWO-SPEED MOTORS For all other SINGLE-PHASE wiring diagrams refer to the manufacturers data on the motor. Basic wiring for motor control – Technical data. Maximum 3 Phase Power = 200 x 415 x 1. The simplest three-phase system is the 3-wire Delta configuration, normally used for transmission of power in the intermediate voltage class from approximately 15,000 volts to 600 volts. This video will show you how to wire up a 9 wire 3 phase motor to a 480 volt system. This wiring diagram provides guidance on how to connect and distribute power in a 240 volt 3 phase system. The below wiring diagram shows how we would assemble a complete motor starter, with a. I have included a picture of the wiring diagram attached to the motor below. A three-phase contactor is an electrical device used to control the flow of electricity between a main source and a load. The wire size and type will depend on. Franklin Electric is a global leader in the production and marketing of systems and components for the movement of water and energy. A capacitor for starting up the motor. Normally, it is found under the right hand aspect from the instrument panel. Energize the contactor. Now connect Hot 1 (red color) from the breaker to the A2 terminal of the switch and again, connect the L2 terminal to the water. Load – This is the device or devices that. Faster starting power. But you typically find these wires in 120V, 240V, and 208V AC systems. If the motor has screw posts in the wiring box, there will be an extra screw post, not connected to anything, for connecting leads 2,3,5 together. and the diagram on the side of the pump is : simulate this circuit – Schematic created using CircuitLab. The below Figure depicts the two methods of connecting the Delta secondary. 240v motor wiring diagram single phasePhase single 240v wire. " Push the starter's "T" terminal wires into the three-phase motor's "T" terminals and tighten the terminal screws with the flat head screwdriver. This diagram will indicate the correct connections for the motor’s power supply, start/stop circuit, and control circuit. Many 3-phase motors allow for two possible line voltages, for example 230/460. An air compressor wiring diagram for a 240v circuit typically includes information on where to connect the incoming power wires, the grounding wire, and the wires that connect to the motor. The supply power is 3-phase 380V,which means between each hot wire, 380 volts can be measured and between the neutral and any of hot wires. (OPTION A). Step 4: Motor Wiring Diagram. pinimg. Many motor nameplates have 230 volts or 115/230 volts. 5 C FPZ, Inc. We begin with a comparison of single-phase (1-phase) and three-phase (3-phase) voltage applications but then illustrate the many ways in which 3-phase motors can be wired to accept high or low voltages, depending on the. Thermally protected L Type. This 3 phase, 3 wire arrangment could lead to an un-safe situation. 5214 † acmepowerdist. Table 1. Voltage between two Hot Phases = 120V x 2 = 240V (1-Φ). To solve the problem an auxiliary, usually weaker, winding is added to the motor and it is offset from the main coil by, say, 30°. Voltage Volts): 240V. Apply the. You said 1+8, but the picture says 1+5 for 240V. kVA capacity remains constant. wiring. . Post navigation. Looking at a 120/208 wye system, the phase voltage would be 120V and the phase-to-phase voltage would be 208V. Press RUN, the frequency rises to 50Hz. Maximum 1 Phase Power per Phase = 200 x 240. Simply put, 480V is what the power source supplies, but the equipment within the system is designed to operate at 460V due to power losses. This diagram will outline the different wires and terminals on the. The most common is nine-wire, but there are also many examples of motors with three, six, or even twelve wires. To install a 240V single phase circuit, just mount the 30A two pole circuit breaker in the metal tracks (designated for two hot busbars) which tightly holds the breakers. Two main parts of motor are rotor and stator. 240V power is used in the US and parts of the world. Blue = Neutral. Electrical Wall Receptacle Outlet Wiring Diagrams. It shows how specific components of the system are wired to each other, and where the three-phase power supply enters the system. #4 · Oct 2, 2020. Revealing four wires inside cord. In a 240 volt 3 phase system, there are three separate phases, or legs, of power. This article will focus on the wiring diagram of a 120/240 volt motor, and how to properly wire it to the power source. With Solved Example. Set rated frequency of motor ( P1-04) and rated speed ( P1-05 ). ELECTRICAL MOTORS 12 Lead, Dual Voltage, Wye Start/Delta Run, Both Voltages or 6 Lead, Single Voltage, Wye Start/Delta Run Motors designed by US Motors for Wye Start, Delta Run may also be used for across the line starting using only the Delta connection. WIRING Connect the motor as shown in the connection diagrams. Source: gidn. Century ac motor wiring diagram 115 230 volts . They can be used as a guide when wiring the controller. Single-phase motors tend to be more sensitive to overvoltage than do 3-phase motors. You may find the latter arrangement to be less expensive than a 3 phase transformer. You need to start by removing the screw holding the air compressor’s cover plate. Wiring 220v capacitor voltage compressor. Connect the Hot Wires. In this motor, you are working with two sets of wires, the electrical cord and a pair of jumper wires that go to the motor windings. Tighten the screws on the contact blocks. Wiring 208v 120v 240v nec iec electricaltechnology3 phase plug wiring diagram 480v 3 phase 6 lead motor wiring diagramDigital 3 phase. Each wire has a specific purpose, which is indicated by its color coding. If performing on site, be sure. phase DE1. Depending on the particular motor and contactors being used, the steps involved may vary slightly. Connect the relay to the control circuit of the contactor. According to NEMA, 460V three-phase is a “Utilization Voltage”, while 480V is a “Distribution Voltage”. either end to center has half the voltage of end-to-end. I got this motor at my university. 240v Ac Single Phase To 120 240 Split Victron Community. It is used to show how the various components of the system are connected together. pdf E207 284TTFNA6026 A-EE7308 EE7308. The power available is 3 phase, 240 volts line to neutral. Generally, Electric supply and service providers install a single phase energy meter when load is less than 7. Featured websites:. 7 cosφ 0. This system, although much better than an open delta 2 pot system, still does not guarantee good balanced power. Swapping B with C does exactly the same thing as does swapping A with C. 144 KW Kilowatts. Phase single volt wire vfd power connection supply trainingHousehold 120 / 240 single-phase 3-wire power distribution Phase wire 208v three 480v 240v single wye power electrical 240vac 208 3phase service pole wiring diagram receptacle supply voltageWiring 220v dayton baldor reversing. Figure 3 - Wiring Diagram for Single Phase 3 HP Motors NOTE: Single voltage (230V) motor, and cannot be connected to 115V. Thread starter Abraham2015; Start date May 27,. Identify the motor winding and starter winding properly. Over 20 years of development has resulted in a robust and durable phase converter capable of powering any load, from hard-starting motors to equipment. To connect at 480V you'll need to pull up the 4,5,6 leads and go with: 1 to T1. Small motors tend to be more sensitive to overvoltage and saturation than do large motors. The circuit size is determined by the required electrical load of the heater which is measured in watts or amps. Step-By-Step Instructions For Air Compressor Wiring Diagram 240v. Here is a website that explains the operation of different types of electric motors without single-phase electric motor diagrams. Dispenser. 200 -240V 480V 480V Phase A Phase C Phase B 230V Delta Connection DE1 L2/N L1/ 200 -240V 200 -240V Nuetral. Sbect to cange itot notice. It was tripping the breaker when starting. Wiring Diagrams for Three-phase Motors. Input: 240v single phase or 415v 3 phase. The motor itself is a single phase, 240v, 3Hp unit. 1-Arbitrarily mark line, (to power), leads 1,2, and 3. Type: 3-phase AC Motor IEC 60034 7. The remaining phase-to-neutral voltage will be √ 3 /2 the phase-to-phase voltage. Single Phase supply 240 Volt Coil - see wiring diagram. It would appear that your motor was set for 240V and the T connections were: 1 to 7 and on to T1. In three-phase motors 2 thermal switches connected in series are placed between the phases of the motor. To make the transformer connections compatible with three-phase supplies we need to connect them together in a particular way to form a Three. For instance , if a module will be powered up and it sends out a new signal of 50 percent the voltage and the technician does not know this, he would think he offers a problem, as he would expect a. This creates a single phase system. It is often used in industrial applications where large amounts of power. The T symbol designation refers to the Terminal or Termination, which in this case is a wire lead that is part of the internal. How to wire a contactor and overload. ) can be connected in between Phase and Neutral through proper protective devices e. Three-phase motors will almost always have a bundle of wires coming out the side, meant for connections to both incoming line power as well as establishing. 7 cosφ 0. Thermal contacts (TB) white M 1~ Z2 - Yellow Z1 - Blue U2 - Black U1 - Red Bridge L1 and L2 if speed controller (S/C) is not required M 1~ LN E White Brown. BUT motor ratings are based on the supply voltage (and current), not the phase voltage. 5 kva step-up transformer ; Three single-phase transformers wired as a 3 phase. Conduit protects all other components of the wiring assembly while switches regulate the flow of electricity. It also includes labels for each of the components, so you can easily. Start stop 3 phase motor control wiring diagrams. First, it’s important to understand that the diagrams contain labels to identify each of the motor’s leads. For use on 110 volts they would be connected in parallel. 77 Beautiful Westinghouse Ceiling Fan Wiring Diagram- Wiring a ceiling aficionado is surprisingly simple. The motor has three wires coming out of it, and according to Auburn Armature Inc (whose sticker is on the newly rebuilt looking motor), they said if we had three phase 460 volts going in, we could just connect the power and it would be fine. 334. Follow. To properly read a cabling diagram, one has to learn how the components within the method operate. Check the bearings to make sure they can spin freely. Basic electrical components to wire a start stop station. Three. The motor has 3 wires coming out of it, then there are 3 I guess you would call them jumper wires. it means 2 phases out of 3 phases are connected. This diagram helps electricians and maintenance personnel understand the overall. The structure of the 1-phase motor determines that the reverse rotation is generally completed by hardware. Dahlender winding. You will actually be running on 208 volts, but that is within range of the motor tolerances. 7. pump motor, 230 V to dispenser switch. Set the multimeter to check continuity. Hot to Neutral here is 120V, to get 240V you need two Hot lines, L1 and L2. When dealing with an electric motor, understanding the wiring diagram is essential. 480 volt single phase motors are pretty rare and most I have seen are more or less OEM type motors for. This wiring should not be used on 240 volt circuits. The electrical code permits such a system to operate without a direct connection to ground. Watch till the end for my Tech Tip. To start, you'll need a 240 volt plug wiring diagram to ensure that you're connecting all the wires correctly. The wiring diagram connects this to L1 and L2 of the three-phase supply, so. I have labelled terminals W1 U1 W2 in red. The motor has a split stator coil that allows for 120V or 240V connection. Ac Sd Controller 3 Phase Motor Wiring Diagram Leeson. Sigma. 240V Motor Wiring Diagram Single Phase. No one seems to recall that set up. Dynamically balanced rotors. Wire Type. I'm sure that the motor is listed and tested for those voltages, but a 2 to 1 voltage change is not possible with a 6 lead 3 phase motor. A split-phase or single-phase three-wire system is a type of single-phase electric power distribution. I show in detail three different methods for powering a three-phase motor with single phase power. Alternate motor suppliers may be used. Three-phase motors will almost always have a bundle of wires coming out the side, meant for connections to both incoming line power as well as establishing connections between windings. 240 volt 3 phase 4 wire 240 volt 3 phase 4 wire Check voltage from A to ground and B to ground and C to ground ( ground lug in panel or disconnect ) this will tell witch phase is high leg, do not use high leg. The rotor is usually made as a squirrel-cage, and it is inserted into the stator’s hole. The torque characteristic won't be as good though. The voltage is applied directly to one hot wire and the other hot is joined together with the neutral wire. UPDATE (31st Jan): From the information provided by pingswept and bt2 in their answers, I think I've come up with a simulation of the. Table 11 Ratings for 120/240 V, 3-Wire, Single-Phase Dwelling Services101 Table 12 AWG and Metric Wire Data 102 Table 13 Electrical Formulas for Amperes, Horsepower, Kilowatts and KVA 103 Table 14 Ratings for 3-Phase, Single-Speed, Full-Voltage Magnetic Controllers for Nonplugglng and Nonjogging Duty 103 Table 15 Ratings for 3-Phase,. 240V/120V, 3 Phase, 4 Wire System @ 60Hz. Size: 97. 3 PHASE INDUCTION MOTOR HEATER. Voltage Rating of. 6 wires are from the motor, 1 for grounding if provided, and 3 (L1-3) from the power supply. For 480V Wye connection, phase voltage would be 277. Make sure the replacement motor may be wired for 220 volt single phase, the same as the existing air compressor circuit, paying close attention to the voltage and amperage which must be within the specs of the. Starting & Stopping of 3-Phase Motor from more than One Place Power & Control diagrams. 3-Phase Wye Chart (Requires 3 transformers) Low Voltage (LV) High Voltage (HV). be careful. Refer to MN408 or MN605 for additional details on lead marking. Inspect the three-phase motor's wiring diagram. The other type of three-phase power is three-phase motor wiring. Reading a 480 volt 3 phase 6 lead motor wiring diagram can be a bit confusing. In this case, that amount is 480 volts. The function of neutral wire in 3 phase 4 wire system is to serve as a return wire for general domestic supply system. 240 v. Three Phase Connections: Part Winding Start: 6 Leads NEMA Nomenclature: WYE or Delta Connected. (Hot 1, Hot 2 or Hot 3). 3 Phase 240V Motor Wiring Diagram. . and the diagram on the side of the pump is : simulate this circuit – Schematic created using CircuitLab. Wiring diagrams, sometimes called “main” or “construc- tion” diagrams, show the actual connection points for the wires to the components and terminals of the controller. Specs. 480V 3 Phase Motor Wiring Diagram Source: 480V 3 Phase Motor Wiring Diagram Source: i. With this approach the 230-volt winding (and connection diagram) is used on the 208-volt pow-er system. Probably like this: simulate this circuit – Schematic created using CircuitLab. (3- phase) Machinery Wiring Diagram for motor loads that total up to 3 times the maximum converter rated current. Note: For single-phase connections and three-phase open delta connections, inputs and outputs may be reversed. To compute the amperage of your 240-volt air compressor, you'll need to multiply the voltage by the unit's wattage. Wiring A 3 Phase 208 Volt Heater240v single phase motor wiring diagram. Step 3. To properly read a cabling diagram, one has to learn how the components within the method operate. The supply voltage is either 240 volts alternating current (VAC) or 480 VAC. Each AC voltage phase is separated by 120° from the other (Figure 1). The inverter input power supply is single phase 240V and it will convert to 3 phase output to your motor. KW 0. Three-phase electric power (abbreviated 3φ) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. Referring to the label, for conversion to running on 220/240V power: The brown motor winding wire needs to be disconnected altogether. Since the motor is a 230/460, and you have a 208V supply, you would wire it low voltage. The disconnect box will have terminals labeled "L1," "L2" and "L3. What Is A Contactor Library Automationdirect Com. Once wired up as a delta bank, the system is now a three phase system and has a phase-to-phase voltage of 240V, the same voltage as the phase voltage. Feeds a 3 phase 240v motor that says it draws 11 amps and a cooling fan that draws 1 amp. Can the GFCI operate correctly without a load neutral connected to it. 7 A = 2 kVA 1000 Three-Phase kVA = Load Volts x Load Amperes x. Check Details. The electrical code permits such a system to operate without a direct connection to ground. Using a pair of diagonal cutters, cut and remove 3 in of rubber insulation around outside of power cord. Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. The single phase induction motor is similar. We are in South Africa which operates at 240V, and when measuring each phase on the 3-phase line we get 480V RMS. There are two main. The neutral wire is shared by all currents returning from the customers’ premises to the supply transformer. 48,000 Volt Amps (VA) per Phase or. You can run three phase motors (240 or 480) from upsized VFD's like you mentioned, or run single phase motors @ 240 volts. Basic electrical components to wire a s. Other load voltages require a transformer after the three-phase panel. A three-phase motor circuit is nearly as efficient as a DC supply. Start winding resistance is PROBABLY greater than run winding resistance. The wiring diagram is roughly as following (sorry, newb here):. e. If undersized wire is used between the motor and the power source, the starting and load carrying cap abilities of the motor will be. Check Details. Prices and Specs. For example, AC or DC then click “Overview” to display the motor types. The new thermostat has three relay outputs: Hi, Med, Lo. A variable frequency drive (VFD) rectifies each pair of phases to dc and inverts the dc to the power for the three-phase output, which means a VFD can be used with single-phase input to operate a three-phase motor. It is most commonly used to switch large amounts of power from a three-phase. machine, they may also require three-phase power. The manual indicates: The equipment is designed for 3 phase 230V power supply (Between each hot wire, 220 volts can be measured) when 2 phases are connected. HP is constant in this case. The L symbol designation refers to the Line, or the incoming circuit wires that provide the power for the motor. Think of it like a triangle. Six wire three-phase electric motors are dual voltage motors. 240V outlets use two 120V wires simultaneously plus a neutral wire to power a single receptacle older homes and appliances may use three prong 240 volt outle. Each of the two top terminals represents one of the opposite poles of the 220-volt power circuit, as do the two bottom terminals. Motor Wiring Diagram 12 Lead, Dual Voltage, Wye Start - Delta Run or Part Winding Start Motors designed by US Motors for Part-Winding Start may also be used for across the line starting using only the full winding connection. It may also show any necessary circuit protection devices, such as fuses or. Thermal contacts (TB) white M 1~ Z2 - Yellow Z1 - Blue U2 - Black U1 - Red Bridge L1 and L2 if speed controller (S/C) is not required M 1~. Close the motor's wiring box. The white neutral wire should also be connected. Phase B, the “high” leg, is not. I cannot find a brown wire at all. 208-230, 230, and 460 volts. For 120 volts, connect the start winding wires to the remaining drum switch terminals. pdf E209 324TTFS6026 A-EE7308 EE7308. 23. Contactor 3 Pole 40 Amp 120 240 V Hog Slat. In this case, high-voltage connections are the same as for delta motors. 3 Phase Motor Starters and Control Circuits. L1 L2 IL1680 230 VOLT SINGLE PHASE LINE YELLOWBLACKREDWHITEGRAYGRAY NOTE: Dual voltage motor, change the red and gray wire to voltage required. EDM Series A-4/5 Diags. Sensor Types Explained. The net output or efficiency of the motor is reduced 2/3rd of its rated capacity. This directs the current through from L2 and directs it through the 3 rd phase on the contactor and overload (L3 & T3). Types Of Wires And Cables For 208V Single-Phase Power. USA T12 T13 Single-Speed / Dual-Voltage Low Voltage (See Motor Nameplate) High Voltage (See Motor Nameplate) Connection DT72 SEW-Eurodrive, Inc. See moreThis video will show you how to wire up a 9 wire 3 phase motor to a 3 phase 240 volt system. Of all types, the twelve-wire motor provides the most options for connecting based on voltage and system configuration (wye or delta). Still using two legs and a neutral of the 3 ph system will yield 240 single phase. Put the voltmeter between lead #3 and one of the other leads in the same #3 group. The wiring, fusing and grounding must comply with the Neutral – Gray wire. Here is a step-by-step guide to help you wire your Baldor 3 phase motor: First, make sure you have the necessary tools and equipment, such as wire strippers, a screwdriver, and electrical tape. available are 208 volt, 240 volt, 480 volt and 600 volt.